b'EN INSTALLATION4 .8Electrical connectionDANGERDanger of death caused by live components!Contact with live parts can lead to serious injury, take the following precautions:- ensure that the power is switched off for all electrical parts- electrical wiring installation must be carried out by qualified personnel and in compliance with the regulations currently in force in the country of destination. Refer to the wiring diagrams.CAUTION- The electrical installation should include a minimum of a type A MCB.CAUTION - Check to ensure that the power supply voltage is as specified in the electric diagram and in data plate.- Burner fuse: 3 Amps.WARNING- Use flexible cables in compliance with the EN 60 335-1 standard. Assure a correct earth WARNING connection.- The wiring section must be minimum 1 mm 2(in any case verify with the standard and local rules).- This control flame is equipped with the post ventilation function. Other versions of the burner are not to be fitted.- Check operation of boiler thermostatic control.- Check operation of Photocell by withdrawing from burner and then covering to simulate flame out condition.30/64'