ENVIROGREEN KITCHEN - TECHNICAL INFORMATION
Heat Output kW |
12-18 |
20-20+20-26 |
26-35 |
35-44+58 |
73 |
80-100 |
CONNECTIONS |
- |
- |
- |
- |
- |
- |
Heating Flow |
1” BSP |
1” BSP |
1” BSP |
1½” BSP |
1½” BSP |
2” BSP |
Heating Return |
1” BSP |
1” BSP |
1” BSP |
1½” BSP |
1½” BSP |
2” BSP |
Drain Off Valve |
½” BSP |
½” BSP |
½” BSP |
½” BSP |
½” BSP |
½” BSP |
Condensate Trap |
22mm dia. plastic |
|||||
WATER CONTENT |
- |
- |
- |
- |
- |
- |
Boiler |
24 litres |
24 litres |
24 litres |
43.5 litres |
54 litres |
75 litres |
FLUE |
- |
- |
- |
- |
- |
- |
Balanced Flue Assembly |
125 (5”) mm dia. |
125 (5”) |
125 (5”) mm dia. |
150 (6”) |
180 (7”) mm dia. |
200 (8”) mm. dia. |
Max. Low Level Flue Length |
1.5 m |
1.5 m |
1.5 m |
1.5 m |
1.5 m |
1.5 m |
Max. High Level Balanced Flue Length |
6 m |
6 m |
6 m |
6 m |
6 m |
6 m |
HEATING SYSTEM (SEALED) |
Fit in accordance with BS 7074, Part 1, BS 5449, OFTEC standards and all other relevant legislation. |
|||||
Preset Pressure Relief Valve |
3 bar |
|||||
WATER SIDE RESISTANCE |
Flow rate to give a nominal output at 10K differential Flow Rate Measured: 1642 kg/h (12-20kW), 2135 kg/h (20-26kW), 2874 kg/h (26-35kW), 3613 kg/h (36-44kW) Flow rate to give a nominal output at 20K differential Flow Rate Measured: |
|||||
PRESSURE JET OIL BURNERS |
ELCO FB 2 K LN 12-58kW and ELCO FB 3 K LN for 73kW and 100kW |
|||||
FUEL |
Kerosene 28 Second Class C2 |
|||||
ELECTRICAL SUPPLY |
230V AC 50Hz 5A |
|||||
TEMPERATURE CONTROL |
Thermostats have an operating tolerance of + 4˚C. |
|||||
Boiler Central Heating Control |
60°C - 80°C |
|||||
Boiler Safety Limit |
110°C |
|||||
Over-run - Fixed |
87°C |
ENVIROGREEN KITCHEN - TECHNICAL INFORMATION
- Details